FREE SHIPPING OFFER
|
Free Shipping within the Lower 48 United States. If you are located outside of the Lower 48 United States, please request a freight quote.
|
Model Number:
|
PTWBB59714
|
Condition:
|
New
|
Description:
|
Infrared Natural Gas Heater - Vacuum Straight Tube - 50k to 175k BTU - 15 ft to 50 ft
|
Features:
|
Straight tube heaters are best for long runs over aisles and for total building heat. Vacuum system's pull products of combustion through the combustion chamber to increase the flame length and improved radiant efficiency. Standard construction includes the first 10' of heat treated aluminized steel tube with all remaining tubes consisting of hot rolled steel tubing.
These straight tube infrared heaters provide an economical alternative for hard-to-heat spaces. Ideal for manufacturing plants, warehouses, hangars, loading docks, work shops, fire stations, garages and more! Great for heating entire buildings or spot heating smaller areas. Can be used in high ceiling areas and entryways. Infrared tube heaters help reduce fuel bills up to 50%. Highly efficient aluminum reflectors can be individually rotated up to 45 degrees. Heavy duty cast iron burner with reliable direct spark ignition system offers 100% gas safety shut-off control. Burner system includes inspection sight glass, diagnostic monitoring light system and step-opening redundant combination gas valve for quiet ignition. Provides up to 25’ outside combustion air capability. Up to 25’ sidewall vent capability. CSA certified. 5 Year Limited Warranty on tubes.
|
Contact Us:
|
Phone (Toll Free): 1-888-257-8607
Email: eBay mail or our customer service email
|
See similar items in our eBay Store
Offers fuel savings up to 70%.
Description & Specification:
PTWBB59714 - 50,000 BTU - 15ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
17-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
15 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 48",Rear 12",Ceiling 6",Below 40",End 30" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 27",Ceiling 6",Below 40",End 30" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
10 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
11 |
WEIGHT LBS |
76.8 |
ASSEMBLY |
Assembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
50000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB59716 - 50,000 BTU - 20ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
22-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
20 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 48",Rear 12",Ceiling 6",Below 40",End 30" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 27",Ceiling 6",Below 40",End 30" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
10 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
11 |
WEIGHT LBS |
100.8 |
ASSEMBLY |
Assembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
50000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB59718 - 50,000 BTU - 30ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
32-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
30 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 48",Rear 12",Ceiling 6",Below 40",End 30" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 27",Ceiling 6",Below 40",End 30" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
10 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
11 |
WEIGHT LBS |
129.6 |
ASSEMBLY |
Assembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
50000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB200336 - 125,000 BTU - 40 ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
DUCT SIZE INCHES |
4 |
OVERALL LENGTH |
22' 9" |
TUBE LENGTH FEET |
20 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 48",Rear 12" Ceiling 6",Below 60",End 30" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 27",Ceiling 6",Below 60",End 30" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
12 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
13 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
BTU |
75000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
VOLTAGE |
120 |
AMPS |
2.4 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
TYPE |
Straight Tube |
PTWBB59872 - 100,000 BTU - 30 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
32-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
30 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 66",Rear 20",Ceiling 6",Below 88",End 40" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 66",Ceiling 6",Below 88",End 40" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
13 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
14 |
WEIGHT LBS |
129.6 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
100000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB59874 - 100,000 BTU - 40 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
42-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
40 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 66",Rear 20",Ceiling 6",Below 88",End 40" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 66",Ceiling 6",Below 88",End 40" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
13 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
14 |
WEIGHT LBS |
158.4 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
100000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB200337 - 175,000 BTU - 40 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
DUCT SIZE INCHES |
4 |
OVERALL LENGTH |
32' 9" |
TUBE LENGTH FEET |
30 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 66",Rear 20" Ceiling 6",Below 101",End 40" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 66",Ceiling 6",Below 101",End 40" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
13 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
14 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
BTU |
125000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
VOLTAGE |
120 |
AMPS |
2.4 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
TYPE |
Straight Tube |
PTWBB200339 - 75,000 BTU - 20 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
DUCT SIZE INCHES |
4 |
OVERALL LENGTH |
42' 9" |
TUBE LENGTH FEET |
40 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 66",Rear 20",Ceiling 6",Below 101",End 40" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 66",Ceiling 6",Below 101",End 40" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
13 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
14 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
BTU |
125000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
VOLTAGE |
120 |
AMPS |
2.4 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
TYPE |
Straight Tube |
PTWBB59930 - 125,000 BTU - 50 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
52-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
50 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 66",Rear 20",Ceiling 6",Below 101",End 40" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 66",Ceiling 6",Below 101",End 40" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
13 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
14 |
WEIGHT LBS |
187.2 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
125000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB59944 - 150,000 BTU - 40 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
42-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
40 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 84",Rear 24",Ceiling 6",Below 106",End 48" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 84",Ceiling 6",Below 106",End 48" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
14 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
15 |
WEIGHT LBS |
158.4 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
150000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB59738 - 150,000 BTU - 50 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
LENGTH FEET |
52-3/4 |
DUCT SIZE INCHES |
4 |
TUBE LENGTH FEET |
50 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 84",Rear 24",Ceiling 6",Below 106",End 48" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 84",Ceiling 6",Below 106",End 48" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
14 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
15 |
WEIGHT LBS |
187.2 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
TUBE CONSTRUCTION |
Hot Rolled Steel |
BTU |
150000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
DESCRIPTION |
Standard Straight Tube |
TYPE |
Negative Pressure |
PTWBB200341 - 125,000 BTU - 40 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
DUCT SIZE INCHES |
4 |
OVERALL LENGTH |
42' 9" |
TUBE LENGTH FEET |
40 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 84",Rear 24" Ceiling 6",Below 106",End 48" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 84",Ceiling 6",Below 106",End 48" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
15 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
16 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
BTU |
175000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
VOLTAGE |
120 |
AMPS |
2.4 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
TYPE |
Straight Tube |
PTWBB200343 - 175,000 BTU - 50 Ft Long
WIDTH INCHES |
13 |
HEIGHT INCHES |
6-1/4 |
DUCT SIZE INCHES |
4 |
OVERALL LENGTH |
52' 9" |
TUBE LENGTH FEET |
50 |
MIN. CLEARANCE COMBUSTIBLE AT 45 DEGREE ANGLE INCH |
Front 84",Rear 24" Ceiling 6",Below 60",End 48" |
MIN. CLEARANCE COMBUSTIBLES AT HORIZONTAL INCH |
Side 84",Ceiling 6",Below 106",End 48" |
MIN. MOUNTING HEIGHT FEET AT 45 DEGREE ANGLE |
15 |
MIN. MOUNTING HEIGHT FEET AT HORIZONTAL |
16 |
ASSEMBLY |
Unassembled |
CONSTRUCTION |
Cast Iron Burner/Aluminum Reflectors |
BTU |
175000 |
BURNER PRESSURE W.C. INCHES |
3.5 |
VOLTAGE |
120 |
AMPS |
2.4 |
GAS INLET PRESSURE MAX. WATER COLUMN INCHES |
14 |
GAS INLET PRESSURE MIN. WATER COLUMN INCHES |
5 |
FUEL TYPE |
Natural Gas |
IGNITION TYPE |
Direct Spark |
TYPE |
Straight Tube |
LIMITED WARRANTY YEARS |
5 on Tubes, 1 on Unit |
Shipping Terms
|
Shipping and Handling: FREE within the Lower 48 United States. All other locations, please contact us for a shipping quote.
Shipping Insurance: All of our products are shipped 100% insured against damage and loss. If you receive a damaged product, please let us know by email and we will arrange for the product to be picked up at the address that it was delivered to. We will pay shipping to have the item returned to our facility. Once we have received the item back, we will ship a replacement immediately, provided stock is available.
|
Warranty and Return Policy
|
All of our products are sold with at least a One Year Manufacturer's Warranty. If you receive an item that becomes inoperative within the manufacturer's warranty period, you will be required to exercise your warranty directly with the manufacturer for the repair or replacement of the product. We will not accept product returns which are covered by a manufacturer's warranty.
|
Feedback Policy
|
We want you to be completely satisfied with your purchase and have a pleasant buying experience with us on eBay. We highly value our outstanding eBay feedback reputation. If anything about your transaction is not to your satisfaction, please contact us BEFORE leaving feedback, inform us of the issue, and we will do our best to resolve the situation to your satisfaction in an effort to earn a positive feedback. Due to our business systems and processes, we leave feedback after receiving feedback from you, our valued customers. We believe this process ensures good communication and problem resolution in advance of posting permanent feedback.
|
|
|